Battery selection for AGVs & mobile robots
Use shift logs, dock charging time, motor peaks and the controller interface to evaluate a replacement battery or specify a custom pack.
Prepare a project briefWhat to specify
| Decision | Inputs to record | How to check |
|---|---|---|
| Shift and charging | Load across the shift, usable runtime, idle periods, dock dwell time and charger output. | Log time and energy on a representative route. Include payload, cold operation, reserve and aging. |
| Motor peaks and fit | Continuous current, startup peak and duration, regen current, voltage cutoff, envelope and mounting. | Check terminal voltage during repeated starts and under maximum payload. Confirm connector, cable exit and service space. |
| Controller and dock | Charger and controller model, pinout, CAN or RS485 message mapping where applicable. | Verify charge enable, state-of-charge reporting, faults and recovery on the proposed sample. |
Cell references for initial screening
Use these source values for an initial comparison. Pack voltage, current capability, physical fit and test evidence depend on the proposed build.
Sample acceptance
Agree the loaded route, payload, usable shift runtime, recharge target and data capture before approving a sample. Log voltage, current and temperature. Review the transport and end-use documentation for the actual pack.
IEC 62619:2022 scope for industrial secondary lithium batteries · Review the evidence checklist